Example - Intermec ESim v4.20 Programmer's Reference Manual

For easycoder c4 bar code label printer
Table of Contents

Advertisement

Some commands may also aff ect the values of other command, for
example if a confi guration label is printed (see U and UP commands),
the print direction is reset to ZT, and if an R Reference Point command
is executed, the label width (see q command) will be changed.

Example

Let us assume that we will use an EasyCoder C4 for direct thermal print-
ing. We will print full width Th ermal Top labels in the peel-off mode
without using the label taken sensor. Th e default communication setup
and character set are acceptable.
Th us, a few setup parameters should be changed in the Direct Mode:
• Density from 10 to 8
• Media feed adjustment from 136 to 110
• Label Taken Sensor from enabled to disabled
Enter the following commands:
Command
D8 ↵
j110 ↵
ON ↵
Intermec EasyCoder ESim v4.20—Programmer's Reference Manual
Chapter 3—Setting Up the Printer
Explanation
CR/LF to start command structure
Set density
Set media feed adjustment for peel-off
operation
Disable label taken sensor