up the single counter by one (1) in each position (last two A-
command lines).
Set the Form Step Value p4 to +3 for the counter Cn used in our
example (see the C-command line). Also refer to "C – Counter".
↵
FK"TEST2"↵
FS"TEST2"↵
C0,5,L,+3,"Counter 0"↵
A180,50,0,3,1,1,N,C0↵
A380,50,0,3,1,1,N,C0+1↵
A580,50,0,3,1,1,N,C0+2↵
FE↵
Th is example illustrates how fi xed text, variable text, and counters
can be used in text fi elds in the Form Edit Mode:
↵
FK"TEST1"↵
FS"TEST1"↵
V00,25,l,"Product name"↵
C0,4,L,+1,"Start serial No"↵
A50,50,0,4,1,1,N,"COMPANY NAME"↵
A50,100,0,3,1,1,N,"Product: "V00↵
A50,150,0,3,1,1,N,"Serial No: "C0↵
FE↵
Combination of several options can also be used in a single text
fi eld:
A50,300,0,3,2,2,R,"Deluxe"V01C1"Combo"↵
:Writes the text "Deluxe" + the contents of variable 01 + the con-
tents of counter 2 + the text "Combo" + the contents of variable
01.
Intermec EasyCoder ESim v4.20—Programmer's Reference Manual
00001
Chapter 7—Commands
00002
00003
33