UC – Command Reply Accept Character Control
Description
Th is command specifi es a prompt acknowledge character which
the printer returns on the RS-232 or USB channel to the host
after each command execution with no error reply before pro-
ceeding with next command.
Syntax
UCp
Parameters
p
1
Remarks
Default is no Command Reply Accept Character (command
UC0).
Parameter p
If command UC is activated, it will replace the <ACK>-character
at end of command US and P.
If error occurs and error report is activated, the error message will
be sent instead.
Example
Command
UC062
US
X50,200,5,400,20
P
102
Intermec EasyCoder ESim v4.20—Programmer's Reference Manual
1
Specifi es the desired reply character by its ASCII decimal value (0-255).
If p
is anything other than numerical characters or the value is zero, there will
1
not be any Command Reply Accept Character (default value).
saved in Flash.
1
Reply Comments
>
>
>
>
Set Command Reply Accept Char-
acter to '>'
Reply error
Draw a box
Print box & reply '>' at ready