Example

Th e form "TEST", edited in the previous chapter, can be retrieved and
printed from any ASCII sending device using this sequence:
Command
FR"TEST"↵
?↵
EASYCODER↵
501SA↵
Dan↵
100000↵
P1,2
In this example we have manually substituted variables for testing pur-
poses.
Note: It is critical to the syntax to send exactly the same
number of variable lines as defi ned for this label form.
26
Intermec EasyCoder ESim v4.20—Programmer's Reference Manual
Explanation
CR/LF to start command structure
Retrieve form
Call for variables
Substitute variable V00
Substitute variable V01
Substitute variable V02
Counter start value C0
Print 2 copies of a single label