Open The Communication Manager Sat Screens; Log In To The P330 Stack Processor With A Direct Connection To The Services Port - Avaya G700 Installation And Upgrades

Media gateway controlled by media server
Hide thumbs Also See for G700:
Table of Contents

Advertisement

Open the Communication Manager SAT Screens

To run SAT:
If you already have a valid telnet session in progress, access the SAT program by typing sat or
1.
dsat at the telnet prompt.
2.
Log in to the Communication Manager as
Enter your login confirmation information as prompted:
- Password prompt. Type your password in the Password field, and click Login or press
again.
- ASG challenge. If the login is Access Security Gateway (ASG) protected, you will see a
challenge screen. Enter the correct response and click Login or press
3.
Enter your terminal type. Accept the default value, or enter the appropriate type for your
computer. For example, you may use type
Windows 98. For Windows 2000, use
The system displays the SAT interface.
Enter SAT commands as appropriate.
4.

Log in to the P330 stack Processor with a Direct Connection to the Services Port

Note: If you are upgrading an S8300/G700 remotely, connect to the customer LAN and
telnet to the IP address of the P330 stack master (that is, the P330 stack
processor running as the stack master). The IP address is the address assigned
on the customer LAN, not 192.11.13.6.
With a direct connection to the S8300 services port, telnet to the S8300 IP address:
1.
Type telnet 192.11.13.6.
Login as craft or cust.
2.
3.
Telnet to the P330 stack master stack processor.
Type telnet <xxx.xxx.xxx.xxx>, where <xxx.xxx.xxx.xxx> is the IP address of
the P330 stack master processor on the customer's LAN.
Login at the Welcome to Avaya P330 screen.
4.
Login: xxx from the planning documentation
Password: xxx from the planning documentation
You are now logged-in at the Supervisor level. The prompt appears as P330-1(super)#.
Note: To check the syntax of a command in the command line interface, type as much
of the command as you know followed by
P330-1(super)#> set help
you will be given the current list of set commands available. If you type:
P330-1(super)#> set interface help
Installation and Upgrades for G700 with S8300 or S8700
555-234-100 — Issue 3 — May 2003
1 Roadmap and Reference: Connection and Login Methods
craft
.
, a terminal type available for Windows NT4.0 or
ntt
.
w2ktt
. For example:
help
Enter
.
Enter