DMD2050E Universal Satellite Modem
2.3.5
Cables
To meet EMC directives, make sure to use shielded cables that have the shield terminated to the
conductive backshells. To meet low voltage directives, use cables that have insulation
flammability ratings of 94 VO or better.
CAUTION
Before you install the mating connectors, first make sure to start the unit and set the
Interface Type (MIL-188-114A, G.703, etc.) from the front panel. If you do not set the
Interface Type, there is a risk of damage to the Universal Interface Module.
2.4
Initial Configuration Check
The unit leaves the factory with preset configuration defaults.
IMPORTANT
The transmit and receive interface type settings vary depending on the options ordered
from the factory.
When you first start the unit, do an inspection of the preset configuration. To lock up the unit,
enter 'IF Loopback Enable' in the Test Menu, or connect a loopback cable from J1 to J2 on the
rear of the unit.
See also:
Chapter 4. User Interfaces
2.4.1
Standard Factory Configuration
Setting
Data Rate
Mode
Satellite Framing
Scrambler
Drop and Insert
Inner FEC
Outer FEC
Modulation
Frequency
Modulator Output Power
MN-DMD2050E Revision 2
Modulator
Demodulator
2.048 Mbps
2.048 Mbps
Closed Network
Closed Network
None
None
V.35 (IESS)
V.35 (IESS)
Disabled
Disabled
1/2 Rate Viterbi
1/2 Rate Viterbi
Disabled
Disabled
QPSK
QPSK
70.000000 MHz
70.000000 MHz
-20 dBm
N/A
Installation
2–4