5.3.4 ALARM (J15)

The Alarm port uses contact closures to identify the status of the unit. Pins 1 through 6 supply
Form C contacts for major alarm status on the modulator and demodulator.
Normally Open or Normally Closed conditions indicate a FAULTED or OFF state.
C = Closed
NO = Normally Open
NC = Normally Closed
Table 5-4. Pinouts for J15 ALARM Port 15-pin Female D Connector
Use the front panel to set up Prompt and Service alarm summaries. Select one summary type for
each alarm type:
Prompt Alarms Summaries
a) Prompt alarms
b) Prompt and Tx Minor alarms
c) Prompt and Tx minor and Tx Major alarms
MN-DMD2050E Revision 2
Label
Description
ALARM J15
Alarm Port
Pin No.
Signal Name
1
Mod Fault - C
2
Mod Fault – NC
3
Mod Fault – NO
4
Demod Fault - C
5
Demod Fault – NC
6
Demod Fault – NO
7
Prompt - C
8
Prompt – NC
9
Prompt – NO
10
Service – C
11
Service – NC
12
Service – NO
13
No Connect
14
AGC Out
15
Ground
Connector Type
15-pin Female D
Signal
Direction
MF-C
No Direction
MF-NC
No Direction
MF-NO
No Direction
DF-C
No Direction
DF-NC
No Direction
DF-NO
No Direction
CEF-C
No Direction
CEF-NC
No Direction
CEF-NO
No Direction
SP1-NO
No Direction
SP1-NC
No Direction
SP2-NO
No Direction
SP2-NC
No Direction
AGC
No Direction
GND
---