Comtech EF Data DMD-2050E Installation And Operation Manual page 272

Universal satellite modem
Hide thumbs Also See for DMD-2050E:
Table of Contents

Advertisement

DMD2050E Universal Satellite Modem
b. BOOTp: When enabled, at boot time, the modem will use the Bootp Protocol to
automatically get names, masks, and IP Addresses of the modem, router, and server
from the Network Manager. This should be consistent with the tag expected by the users
Bootp Server (see the next menu selection for setting the BOOTp TAG). If Bootp is not
enabled, the modem will ignore the BOOTp Tag setting.
c. NON-VOL: This will allow for setting up all required IP Addresses and will store the
information to the non-volatile memory. Upon power cycle, the modem will restore the
saved settings into the correct fields.
d. IP TEST: The IP Test selection is similar in behavior to the Default selection. When
enabled, the following preset parameters will be programmed and will not change until
the selection is changed. To edit these parameters, change the boot mode to NON-VOL.
2. BOOT SERVER TAG: This allows for the selection of the operating boot tag when operating in
the BOOTp Mode. The default setting of 206 is automatically selected when the boot mode is set
to 'DEFAULT' (factory preset mode).
3. MODEM HOST: This displays the unit Host name that is operating, such as "DMD20". This is a
read only display.
4. IP ADDR MASK: This will allow for the entry of the IP Address Mask. This will need to be
entered based on the Network settings. Refer to your IP Administrator if you do not know this
address for the correct address setting. Example IP Address Mask setting: 255.255.000.000.
5. MODEM IP ADDR: This will allow for the entry of the Modem's individual network IP Address.
Each device on the network will have a unique address. Refer to the IT administrator for the
correct address setting. Example Modem IP Address setting: 172.018.100.215.
6. SERVER IP ADDR: This allows for the setup of the Network Server IP Address. This section
refers to the Host that will be used to optionally boot the DMD20 on power-up and is the SNMP
Trap Server. This IP Address needs to be consistent with the Modem IP Address. Broadcast
MN-DMD2050E Revision 2
MODEM IP ADDR
SERVER IP ADDR
ROUTER IP ADDR
IP MASK
MODEM IP ADDR
SERVER IP ADDR
ROUTER IP ADDR 192.168.000.102
010.000.000.001
010.001.001.001
010.000.001.001
255.255.255.000
192.168.000.238
192.168.000.101
TCP/IP Ethernet Setup
F–2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents