Chapter 3: Initial System Configuration
Now add a static entry to the ARP table and ping the Console Server to assign the IP address to the console server. In the
example below, a Console Server has a MAC Address 00:13:C6:00:02:0F (designated on the label on the bottom of the unit)
and we are setting its IP address to 192.168.100.23. Also the PC/workstation issuing the arp command must be on the same
network segment as the Console Server (that is, have an IP address of 192.168.100.xxx)
• Type arp -s 192.168.100.23 00-13-C6-00-02-0F (Note for UNIX the syntax is: arp -s 192.168.100.23
00:13:C6:00:02:0F).
• Type ping -t 192.18.100.23 to start a continuous ping to the new IP Address.
• Turn on the Console Server and wait for it to configure itself with the new IP address. It will start replying to the ping at
this point.
• Type arp –d to flush the ARP cache again.
3.1.2

Browser connection

• Activate your preferred browser on the connected computer and enter https://192.168.0.1 The Management Console
supports all current versions of the popular browsers (Internet Explorer, Mozilla Firefox, Google Chrome, Apple Safari and
more)
• You will be prompted to log in. Enter the default administration username and administration password (Username: root
Password: default)
Note: Console Servers are factory configured with HTTPS access enabled and HTTP access disabled.