Custom Check; Sms Command - Tripp Lite B092-016 Owner's Manual

Console server management switch console server with poweralert console server
Hide thumbs Also See for B092-016:
Table of Contents

Advertisement

Chapter 7: Alerts, Automated Response and Logging
7.1.8

Custom Check

This check allows users to run a nominated custom script with nominated arguments whose return value is used as an Auto-Response
trigger event:
• Click on Custom Check as the Check Condition
• Create an executable trigger check script file e.g. /etc/config/test.sh
#!/bin/sh
logger "A test script"
logger Argument1 = $1
logger Argument2 = $2
logger Argument3 = $3
logger Argument4 = $4
if [ -f /etc/config/customscript.0 ]; then
rm /etc/config/customscript.0
exit 7
fi
touch /etc/config/customscript.0
exit 1
• Enter the Script Executable file name (e.g. /etc/config/test.sh)
• Set the Check Frequency (i.e. the time in seconds between re-running the script) and the Script Timeout (i.e. the
maximum run-time for the script)
• Specify the Successful Return Code. An Auto-Response is triggered if the return code from the script is not this value
• Enter Arguments that are to be passed to the script (e.g. with a web page html check script, these Arguments might
specify the web page address/DNS and user logins)
• Check Save Auto-Response
7.1.9

SMS Command

An incoming SMS command from a nominated caller can trigger an Auto-Response:
• Click on SMS Command as the Check Condition
• Specify which Phone Number (in international format) of the phone sending the SMS message
• Set the Incoming Message Pattern (PCRE regular expression) to match to create trigger event
Note: The SMS command trigger condition can only be set if there is an external USB cellular modem detected