Interface Module/Interface
Cooling Module
The Interface Module or Interface Cooling Module is an optional finishing device that
is used in conjunction with other optional finishing devices.
What is the difference between the two modules?
Both modules enable communication and provide a paper path between the print engine
and any attached finishing device/devices. The Interface Cooling Module goes a step
further in that it contains additional fans and associated duct work. These fans and duct
work aid in cooling the outgoing printed media.
The correct module for your machine configuration
The specific type of module available depends on the machine configuration:
The Interface Module is available with a machine configuration that is either D110
or D125 (either Copier/Printer or Printer only).
The Interface Cooling Module is available only with the D136 configuration (either
Copier/Printer or Printer only).
Xerox
®
D95/D110/D125/D136 Copier/Printer
User Guide
19