Appendix A. Using The Hex Dump - Genicom GEK 00031B Programmer's Manual

Genicom printer user manual
Table of Contents

Advertisement

APPENDIX A. USING THE HEX DUMP

30 31 32 33 34 35 36 37 38 39 41 42 43 44 45 46
OD 0A 54 48 45 20 54 57 4F 20 44 4F 54 53 20 59
4F 55 20 4A 55 53 54 20 53 41 57 20 57 45 52 45
20 41 20 52 45 53 55 4C 54 20 4F 46 20 41 20 43
41 52 52 49 41 47 20 52 45 54 55 52 4E 20 41 4E
44 20 4C 49 4E 45 20 45 45 45 44 2E 0D 0A 41 4C
4C 20 43 4F 4E 54 52 4F 4C 20 43 48 41 52 41 43
54 45 52 53 20 41 52 45 20 52 45 50 52 45 53 45
4E 54 45 44 20 42 59 20 44 4F 54 53 20 54 48 49
53 20 44 4F 54 20 1B 20 49 53 20 41 4E 20 45 53
43 41 50 45 20 43 4F 44 45 2E 0D 0A 41 20 44 4F
54 20 54 4F 20 54 48 45 20 52 49 47 48 54 20 4F
46 20 41 20 48 45 58 20 43 4F 44 45 20 4D 45 41
4E 53 20 54 48 41 54 20 54 48 45 20 50 49 20 4C
45 41 44 20 57 41 53 20 53 45 54 20 41 54 20 54
48 41 54 20 54 49 4D 45 2E 0D 0A 53 45 45 20 54
48 45 20 44 4F 54 53 20.20.20.20.49 4E 20 54 48
GEK-00029B
A printout of hexadecimal data is useful primarily to application
programmers or service representatives as a debugging or
troubleshooting tool.
With the printer Offline, enable the hex dump mode of printing by
pressing:
◄ or ► (left or right) menu browse pushbutton until Set Up is
displayed in the lower right corner of the LCD
▼ (down) menu browse pushbutton
◄ or ► (left or right) menu browse pushbutton until Select Filter
is displayed in the lower right corner of the LCD
▼ (down) menu browse pushbutton
◄ or ► (left or right) menu browse pushbutton until appropriate
( Serial , Parallel (1284) , or Expansion 1 or Expansion 2 ) port is
displayed in the lower right corner of the LCD
▼ (down) menu browse pushbutton
◄ or ► (left or right) menu browse pushbutton until Hex Dump
is displayed in the lower right corner of the LCD
Select pushbutton
Hex dump causes data received from the host to be printed out in
ASCII form. A sample is shown below.
The hexadecimal printout is shown on the left side and the equivalent
plain text is shown on the same line at the right. Exceptions: ASCII
control code characters below hexadecimal 20 are printed out as
periods on the right side. An SP or hexadecimal 20 causes a blank
apace in the equivalent print position.
By examining the printout, you can see what data was actually sent
to the printer.
261
0123456789ABCDEF
..THE TWO DOTS Y
OU JUST SAW WERE
A RESULT OF A C
ARRIAG RETURN AN
D LINE FEED...AL
L CONTROL CHARAC
TERS ARE REPRESE
NTED BY DOTS THI
S DOT . IS AN ES
CAPE CODE...A DO
T TO THE RIGHT O
F A HEX CODE MEA
NS THAT THE PI L
EAD WAS SET AT T
HAT TIME...SEE T
HE DOTS
IN TH
5000 Series Programmer's Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

5000 series

Table of Contents

Save PDF