GENERAL PRINTER OPTIONS DEFINITIONS

H Bits
Function
01-32
01
Prime
02
Interrupt
03
DEL
04
DEL
05-06
Reserved.
07
Underline character
08
PI Lead
09
ACK lead
Character
10
conversion to space.
11
CR
12
FF
13
LF
14
VT
15
DC3
16
DC1
17
Busy
Busy/Demand per
18
character.
Software control of
19
Busy.
20
Busy
21
Busy
22
Busy
23
ACK
24
ACK
25
Data leads
26
Busy is active
27
PI is active
28
PI
29
STB is active
30
SELECT is active
31
PO is active
32
FAULT is active
H Bits
Function
33-64
33
Demand delay.
Set ACK delay from
34-35
Strobe.
Set ACK Pulse
36-37
Width.
38-40
Reserved.
Used with strap 10 to select space character substitution. 41 corresponds with Bit 1 of the
41-48
character code.
49-64
Reserved.
GEK-00029B
I/F Hardware Straps
If Enabled
High = Buffer Clear.
On all Control Codes.
Does not cause an Interrupt.
Does not cause Prime.
Treated as CR.
Causes Interrupt.
Does not reflect
ONLINE/LOCAL status. 05
must be enabled.
Enabled. (See 41-48.)
Not decoded.
Not decoded.
Not decoded.
Not decoded.
Not decoded.
Not decoded.
Does not reflect ACK.
Enabled.
Disabled
Does not reflect
(ONLINE/LOCAL) FAULT/PO
status.
Does not reflect (FAULT)
ONLINE/LOCAL status.
Does not reflect (PO)
ONLINE/LOCAL/PO status.
Does not reflect PO.
Does not reflect FAULT.
0-7 are active high.
High.
High.
Enabled.
High.
High.
High.
High.
If Enabled.
Disabled.
269
If Disabled
Low = Buffer Clear.
Disabled on all Control Codes, except
LF, VT, FF, CR, DC1 and DC3.
Causes an Interrupt.
Causes Prime.
Printed.
Does not cause Interrupt.
Reflects ONLINE/LOCAL status.
Disabled.
Generate an Interrupt.
Generate an Interrupt.
Generate an Interrupt.
Generate an Interrupt.
Generate an Interrupt.
Generate an Interrupt.
Reflects ACK.
Disabled.
Enabled.
Reflects (ONLINE/LOCAL) FAULT/PO
status.
Reflects (FAULT) ONLINE/LOCAL
status.
Reflects (PO) ONLINE/LOCAL/PO
status.
Reflects PO.
Reflects FAULT.
0-7 are active low.
Low.
Low.
Disabled.
Low.
Low.
Low.
Low.
If Disabled
Enabled.
34
35
Delay
Disable
Disable
None
Disable
Enable
1 µsec
Enable
Disable
2 µsec
Enable
Enable
3 µsec
36
37
Width
Disable
Disable
None
Disable
Enable
1 µsec
Enable
Disable
2 µsec
Enable
Enable
3 µsec