Double Density Plot Mode Format
Chapter 4. Printronix P Series Emulation
1. Send the even dot plot control code EOT (04 hex) or control
sequence "SFCC d", followed by a line of data.
2. Send a line terminator, which causes the printer to plot the
contents of the buffer. The paper does not advance in double
density plot; the printer now waits for the second line of data.
3. Send the odd dot plot control code ENQ (05 hex) or control
sequence "SFCC e" and a second line of data, followed by a line
terminator.
▪
A line feed (0A hex) used as the line terminator causes the
contents of the buffer to be plotted and the paper advances a
single dot row, based on the vertical density of the current
mode. A CR (if CR = CR + LF is configured) may also be used
with the same result.
▪
A form feed (0C) hex used as the line terminator causes the
contents of the buffer to be plotted and the paper to advance
to the top of the next form.
100