Table 46
Decimal
Hex
Error
Error
0
00H
1-8
01H -
08H
9
09H
10
0AH
210 Library Error Codes
Error Codes and Recovery Procedures
Description
Error code not set.
Failed library
controller self test.
Failed translate motor
test.
Failed vertical motor
test.
Recovery Method
Power cycle the library.
Observe the LEDs on the back of the library
controller card. See
on page 130 to understand what the LEDs may
indicate.
01h through 08h are controller tests. These errors
are possible only on power-up.
Power cycle the library.
Observe the LEDs on the back of the library
controller card. See
on page 130 to understand what the LEDs may
indicate.
If failure persists, the library controller card
may be faulty.
Cannot translate the transport.
Check for a possible obstruction in the
transport pathway and remove it.
The umbilical cable may be faulty.
If the transport moves a little, but cannot fully
rotate around the assembly, a faulty motor is
indicated.
Occurs when trying to sense if the transport
assembly moves vertically. If the assembly does not
move:
Ensure that the motor leads are connected to
the vertical motor and the vertical lift board.
Check the umbilical cable under the translate
frame.
Interpreting Library LEDs
Interpreting Library LEDs