Historical Performance Data; Enabling Historical Performance Collection San Wide; Enabling Historical Performance Collection For Selected Fabrics; Disabling Historical Performance Collection - Brocade Communications Systems Brocade BladeSystem 4/24 User Manual

Supporting dcfm 10.4.x
Hide thumbs Also See for Brocade BladeSystem 4/24:
Table of Contents

Advertisement

Historical performance data

Performance should be enabled constantly to receive the necessary historical data required for a
meaningful report. The following options and features are available for obtaining historical
performance data:
"Performance management requirements"

Enabling historical performance collection SAN wide

To enable historical performance collection, select Monitor > Performance > Historical Data
Collection > Enable SAN Wide.
Historical performance data collection is enabled for all fabrics in the SAN.

Enabling historical performance collection for selected fabrics

To enable historical performance collection for selected fabrics, complete the following steps.
1. Select Monitor > Performance > Historical Data Collection > Enable Selected.
2. Select the fabrics for which you want to collect historical performance data in the Available
3. Click the right arrow to move the selected fabrics to the Selected table.
4. Select the Include newly discovered fabrics check box to automatically add all newly
5. Click OK.

Disabling historical performance collection

To disable historical performance collection on all fabrics, select Monitor > Performance >
Historical Data Collection > Disable All.
DCFM Professional Plus User Manual
53-1001774-01
Collect historical performance data from the entire SAN or from a selected device.
NOTE
Virtual Fabric logical ISL ports are not included in performance collection.
Persist data on every polling cycle (5 minutes).
Store up to 606 records (maximum) for each port. Most ports require 600 KB disk space;
however, the 256-Port Director requires 7GB disk space.
Use the RRD (Round Robin Database) style aging scheme.
Enable 5 minute, 30 minute, 2 hours and 1 day granularity.
Support interpolation for up to 6 data points.
Generate reports. For instructions on generating reports, refer to
reports"
on page 321.
The Historical Data Collection dialog box displays.
table.
discovered fabrics to the Selected table.
Historical performance data collection is enabled for all selected fabrics.
11
"Generating performance
297

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: