Control Panel
5.5.3

Codepad Fire Alarm

The horn speaker emits a distinct fire sound when you press the [4] and [6] keys
simultaneously.
Contact your installer to disable the codepad fire alarm function or to silence the codepad fire
alarm.
5.5.4
Codepad Medical Alarm
An audible codepad Medical Alarm activates when you press [7] and [9] simultaneously.
Contact your installer to disable the codepad medical alarm function or to silence the codepad
medical alarm.
5.5.5
Codepad PIN Error (Access Denied)
Codepad PIN error restricts the number of times an invalid user code can be used in an
attempt to operate the system. When the number of incorrect code attempts equals the
number programmed by your installer, the system activates an alarm condition. If reporting
back to a security monitoring station, the system sends an Access Denied report.
To shutdown and lockout a codepad for a period of time (0 sec to 150 sec), ask your installer
to program this function.
5.6
Isolating Zones
Use isolating zones to manually disable one or more zones before arming the system. Once a
zone is isolated, you can access that zone during the armed state without activating an alarm.
For example, you need to isolate a zone because before arming the system a PIR detector may
be false alarming, or you need to leave a pet inside a particular zone while away.
Isolating zones is performed by one of two methods. Method two is optional and only allows
those user codes programmed by your installer to have access to isolate zones.
5.6.1
Standard Isolating
Standard isolating allows all operators to isolate zones without knowing a valid user code.
How to Isolate a Zone
1.
2.
3.
5.6.2
Code to Isolate
This method restricts only those User Codes with the Code to Isolate priority level to isolate
zones.
If any User Code has this priority level, the method of standard isolating does not function.
How to Isolate a Zone
1.
Bosch Security Systems, Inc.
Press the [*] button twice to enter the Isolating Mode. Three beeps are heard and the
STAY indicator flashes.
Enter the zone number (1 to 8 / 16), followed by the[*] button (for example, [1*] = Zone
1, [2*] = Zone 2). Each zone to be isolated has a corresponding zone indicator that
flashes. If you selected an incorrect zone to be isolated, enter the incorrect zone number
again followed by the [*] button. Repeat Step 2 if more than one zone is to be isolated
until all zones to be isolated are selected.
Press the [#] button after all selected zones are isolated. Two beeps are heard and the
system returns to the disarmed state.
Press the [*] button followed by your User Code and the [*] button again to enter the
Isolating Mode (for example, [*2580*]). Three beeps sound and the STAY indicator
flashes.
Operation with ICON LCD Codepad | en
User's Guide
17
2017.09 | 04 | F.01U.298.028