Figure 208 Adding a New Location Probability Region
5. Optionally, you can save the location region as the exterior walls. 100% attenuation can be selected to force
VisualRF to only place devices inside of the selected region. No device will ever be placed outside of the
probability region when 100% attenuation is selected. 100% attenuation is only recommended for tall
buildings where it is extremely unlikely that any user is located outside of the building. No heat map or
attenuation grid is calculated for devices outside of the 100% attenuation region.

Adding an IDF

To add an IDF to VisualRF, follow these steps:
1. In the Edit menu, select the Draw Region option.
2. Outline the desired IDF region. Double-click to end the outline process.
3. Name the region, select a Region Type of IDF, and select OK, as shown in
Figure 209 Adding a new IDF Region
Now that the IDF is defined you will see a green IDF icon on your floor plan. Double click that icon to navigate
into the IDF.
1. Add a rack to the IDF by selecting the Add Empty Rack icon and dragging it to the background.
2. To add a planned device, select the Add Planned Device icon to view the Manually Provision Rack Gear
menu. Select the device type in the Type menu, and then find the device you want to add. Drag it into the
rack at the appropriate location.
3. To add a wired device that is currently being monitored by AMP, select Add Deployed Device.
4. Locate the device to be added.
5. Drag the device to the appropriate location in the rack, as shown in
Dell PowerConnect W-AirWave | User Guide
Figure
209.
Figure
210.
Using VisualRF | 273