The Edit button edits the default credentials for newly discovered devices. To modify the credentials for
existing devices, use the APs/Devices > Manage page or the Modify Devices link on the APs/Devices > List
page.
NOTE: Community strings and shared secrets must have read-write access for AMP to configure the devices. Without read-write
access, AMP may be able to monitor the devices but cannot apply any configuration changes.
2. Browse to the Device Setup > Communication page, locate the SNMP Settings section, and enter or revise
the following information.
Table 26 Device Setup > Communication > SNMP Settings Fields and Default Values
Setting
SNMP Timeout
SNMP Retries
3. Locate the SNMP v3 Informs section. Select Add New SNMP v3 User to reveal its configuration section.
AMP users will need to configure all v3 users that are configured on the controller; the SNMP Inform receiver
in the AMP will be restarted when users are changed or added to the controller.
Username - Username of the SNMP v3 user as configured on the controller.
Auth Protocol - Can be MD5 or SHA. The default setting is SHA.
Auth and Priv Passphrases - Enter the auth and priv passphrases for the user as configured on the
controller.
Priv Protocol - Can be DES or AES. The default setting is DES.
4. Locate the Telnet/SSH Settings section, and complete or adjust the default value for the field.
shows the setting and default value.
Table 27 Device Setup > Communication > Telnet/SSH Settings Fields and Default Values
Setting
Telnet/SSH Timeout
(3-120 sec)
5. Locate the HTTP Discovery Settings section and adjust the default value.
default value.
Table 28 Device Setup > Communication > HTTP Discovery Settings Fields and Default Values
Setting
HTTP Timeout
(3-120 sec)
Dell PowerConnect W-AirWave | User Guide
Table 26
lists the settings and default values.
Default
Description
3
Sets the time, in seconds, that AMP waits for a response from a device after sending an
SNMP request.
3
Sets the number of times AMP tries to poll a device when it does not receive a response
within the SNMP Timeout Period or the Group's Missed SNMP Poll Threshold setting (1-100).
If AMP does not receive an SNMP response from the device after the specified number of
retries, AMP classifies that device as Down.
Default Description
10
Sets the timeout period in seconds used when performing Telnet and SSH commands.
Default
Description
5
Sets the timeout period in seconds used when running an HTTP discovery scan.
Table 27
Table 28
shows the setting and
Configuring AMP | 53