14. To configure Symbol settings, locate the Symbol section and adjust these settings as required.
describes the settings and default values of this section.
Table 49 Symbol Fields and Default Values
Setting
SNMP Version
Client Inactivity
Timeout (3-600 min)
Symbol Controller
CLI Communication
Web Config
Interface
15. To configure settings specific to Dell PowerConnect W-Series, locate the Dell PowerConnect W section and
adjust these settings as required. Table 50 describes the settings and default values of this section.
Table 50 Dell PowerConnect W Fields and Default Values
Setting
SNMP Version
Offload WMS
Database
Dell PowerConnect
W UI Config
16. To configure settings for 3Com, Enterasys, Nortel, or Trapeze devices, locate the 3Com/Enterasys/Nortel/
Trapeze section and define the version of SNMP to be supported.
17. To configure support for routers and switches in the group, locate the Routers and Switches section and
adjust these settings as required. This section defines the frequency in which all devices in the group polled.
These settings can be disabled entirely as desired.
section.
Table 51 Routers and Switches Fields and Default Values
Setting
Read ARP Table
Read CDP Table for
Device Discovery
78 | Configuring and Using Device Groups in AMP
Default Description
2c
Specifies the version of SNMP used by AMP to communicate to the device.
3
Sets the minutes of inactivity after which a client associated to a Symbol AP will be
considered "inactive." A lower value typically provides a more accurate representation of
current WLAN usage.
NOTE: For other APs, AMP has more precise methods to determine when inactive clients are
no longer associated to an AP.
Telnet
The connection type to support the command-line interface (CLI) connection. The options are
Telnet and secure shell (SSH). This is supported for WS5100, RFS4000, RFS6000 and RFS7000
devices only.
Yes
Enables or disables the http/https configuration page for the Symbol 4131 devices.
Default Description
2c
The version of SNMP used by AMP to communicate to the AP.
No
Configures commands previously documented in the Dell PowerConnect W-AirWave Best
Practices Guide at support.dell.com/manuals. When enabled, this feature allows AMP to
display historical information for WLAN switches.
Changing the setting to Yes pushes commands via SSH to all WLAN switches in Monitor Only
mode without rebooting the controller. The command can be pushed to controllers in manage
mode (also without rebooting the controller) if the Allow WMS Offload setting on AMP Setup >
General is changed to Yes.
Yes
This setting selects whether you'd like to configure your Dell PowerConnect W-Series devices
using the Groups > Dell PowerConnect W Config method (either global or group) or using
Templates.
Default
Description
4 hours
Sets the frequency in which devices poll routers and switches for Address Resolution
Protocol (ARP) table information. This setting can be disabled, or set to poll for ARP
information in a range from every 15 seconds to 12 hours.
4 hours
For Cisco devices, sets the frequency in which devices poll routers and switches for Cisco
Discovery Protocol (CDP) information. This setting can be disabled, or set to poll for CDP
neighbor information in a range from every 15 seconds to 12 hours.
Table 51
describes the settings and default values of this
Dell PowerConnect W-AirWave | Version 7.3