NEC Express5800/340Hb-R N8800-047F User Manual page 223

Hide thumbs Also See for Express5800/340Hb-R N8800-047F:
Table of Contents

Advertisement

Procedure in ft server utility
1.
Select the target CPU module by using the ft server utility.
2.
Check the current state of the target CPU module with the LEDs.
3.
Select the dump acquisition method with [Dump] of the target CPU module and click the
[Harvest] button.
A certain time is required for the dump acquisition.
The dump is stored as %SystemDrive%\NECDump\MEMORY.DMP on the server.
The result of the dump acquisition can be confirmed in the event log.
Sample screen of ft server utility
Installing and Using Utilities 5-65
[CPU Module]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/340hb-r n8800-073f

Table of Contents