NEC Express5800/340Hb-R N8800-047F User Manual page 108

Hide thumbs Also See for Express5800/340Hb-R N8800-047F:
Table of Contents

Advertisement

3-32 Windows Setup and Operation
Models supporting the RDR function
This section explains the procedure for replacing a disk which is duplexed by the RDR function at
disk level when a failure occurs to the disk.
Below describes an example of locating a failure in the disk in the Slot 2 of the PCI module for
Group1 by "How to Locate Failed Disks".
1.
From [Start], select [All Programs] - [RDR] - [RDR Utility] to start [RDR Utility].
2.
Remove the disk in the Slot 2 of the PCI module for Group1.
3.
Insert a new disk to the Slot 2 of the PCI module for Group1.
IMPORTANT:
Insert a disk which has the same capacity with the one inserted in the Slot 2 of the PCI
module for Group2, and which is new or physically formatted.
4.
Update the display of [RDR Utility], and confirm that the new disk is displayed and the LEDs
of the PCI module and the disk illuminate green.
5.
Right-click the [RDR Virtual Disk x](x=1,2,3) which is constructed by the replaced disk (Slot
2 of the PCI module for Group1) and click [Resynchronize RDR Virtual Disk].
6.
Synchronization of the disk and the paired disk starts.
7.
When [Op State: State] of [RDR Virtual Disk x](x=1,2,3) becomes [Duplex] and [Status]
becomes [None], the synchronization is completed.