3.5.2

SCALANCE X208 TP ports

Connector pinout
On the SCALANCE X208, the TP ports are implemented as RJ--45 jacks with MDI-X
assignment (Medium Dependent Interface–Autocrossover) of a network component.
Figure 3-4
Table 3- 5
Pin number
Pin 8
Pin 7
Pin 6
Pin 5
Pin 4
Pin 3
Pin 2
Pin 1
NOTICE
TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45
TP port.
With the IE FC cables and IE FC RJ-45 plug 180, an overall cable length of up to 100 m is
permitted between two devices depending on the cable type.
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
RJ-45 jack
Pin assignment
Product properties
3.5 SCALANCE X208
Assignment
n. c.
n. c.
TD-
n. c.
n. c.
TD+
RD-
RD+