Settings In Hw Config; Configuring Alarms - Siemens SCALANCE X-200 Operating Instructions Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-200:
Table of Contents

Advertisement

8.2

Settings in HW Config

8.2.1

Configuring alarms

Procedure
1. Open the dialog with the general settings. In this dialog, you will find settings that apply to
2. To open the dialog, select the device whose settings you want to change. In the lower
3. Double-click on slot 0 to open the properties dialog of the PROFINET interface. As an
4. Then select the "Parameters" tab. Here, you can make the following settings:
Redundant power supply
Not monitored
The failure of one of the two power supplies does not cause an alarm to be generated.
Monitored
The failure of one of the two power supplies causes an alarm.
C-PLUG
Not monitored
No alarm results from a C-PLUG error.
Monitored
A C-PLUG error causes an alarm.
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
the entire device.
half of the station window, there is a detailed view of the selected device.
alternative, the properties dialog can also be opened by right-clicking on slot 0 and
selecting the "Object Properties" entry from the context menu.
PROFINET IO functionality
8.2 Settings in HW Config
249