6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)
Utilization
Displays the port utilization as a percentage (%). If the bus utilization is less than 1%,
nothing is displayed. Depending on the frame length (system dependent), the display can
deviate by up to 20% since the proportion of pauses between frames increases the shorter
the frame.
Max. Utilization
Displays the peak value of port utilization as a percentage (%).
Note
The Utilization value is calculated from the incoming frames. Here, both correct and bad
frames are relevant. Outgoing frames are not taken into account in the calculation of this
value.
Syntax of the Command Line Interface
Table 6- 32
Command
info
types
sizes
errors
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
Statistic - CLI\STAT>
Description
Shows statistical information on
sent and received frames.
Displays information on the type
of the sent and received frames.
Displays information on the
length of the sent and received
frames.
Displays information on bad
sent and received frames.