Product properties
3.28 Displays
3.28.4

Redundancy manager indicator (green LED)

Redundancy manager indicator (green LED)
The LED signals that the IE Switch X-200 can adopt the following statuses:
Device type SCALANCE
XF204
X208
XF208
X216
X224
X204-2
X204-2TS
XF204-2
X206-1
XF206-1
X212-2
X204-2LD
X206-1LD
X212-2LD
X202-2IRT
X204IRT
XF204IRT
X204 IRT PRO
X202-2P IRT PRO
X201-3P IRT PRO
X202-2P IRT
X201-3P IRT
X200-4P IRT
1. The device is redundancy manager. The ring is closed.
2. The redundancy manager has switched over. The ring is interrupted.
3. The redundancy manager is disabled.
Note
The status of the redundancy manager and standby are displayed as a double function
by a single multicolor LED. This is identified on the device by RM.
It changes its color depending on the function (redundancy function -> green, standby
function -> yellow).
In Web Based Management, the LED is labeled differently depending on the function
(redundancy function, basic status -> label RM, standby function -> label SB).
124
LED lit green
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
LED flashes green
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Operating Instructions, 12/2011, A5E00349864-19
LED not lit
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
SCALANCE X-200

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents