Configuration / diagnostics using remote mechanisms
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)
Syntax of the Command Line Interface
Table 6- 20
Command
info
scontrol [C|A].
sclose [yes|no]
setec
<Event> <Index> <E|D>
<E|D> <E|D>
206
Agent Event Configuration - CLI\AGENT\EVENT>
Description
Shows the current event configuration.
Selects how the signaling contact works:
Conventional
An error/fault is displayed by the LED and
the signaling contact opens.
Aligned
The signaling contact can be opened or
closed as required regardless of a
fault/error.
Switches the signaling contact, if this in
"aligned" mode:
Yes
The contact is closed.
No:
The contact is opened
Specifies how an IE switch reacts to system
events. You can enter the following values for
the <Event> parameter:
CW
LC
AF
PM
FC
RD
SB
LD
If an event is specified, the configured
actions are formed for each event.
The three parameters <E> or <D> configure
the reactions of the IE switch in the order:
E-mail
Trap
Entry in the log table
Example: If you only want to send an E-mail
when there is a Link Change, enter the
following command:
setec LC E D D
Comment
Administrator only.
Administrator only.
Administrator only.
Cold/Warm Start
Link Change
Authentication
Failure
Power M12
Change
Fault State Change
Redundancy Event
Standby Event
Loop Detection
Operating Instructions, 12/2011, A5E00349864-19
SCALANCE X-200