6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)
Indicates the number of collisions that have occurred.
Note
X-200IRT IE switches work in the cut-through mode.
If a frame is received with a bad checksum, the forwarding of the frame is aborted
prematurely and the frame is therefore shortened. The counter for CRC errors is
incremented.
If the frame involved is a frame with a length of 64 bytes, the counter for undersize errors is
also incremented due to the shortening of the frame
Syntax of the Command Line Interface
Table 6- 35
Command
errors
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
Statistic Packet Error - CLI\INFORM>
Description
Displays statistical information
on received errors.