6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)
6.3.2

LED simulation

Display of the operating state
IE Switches X-200 have several LEDs that provide information on the operating state of the
devices. Depending on its location, direct access to the IE Switch X-200 is not always
possible. WBM therefore provides a simulated display of the LEDs.
In the dialog (see below), you can see a schematic representation of an IE Switch X-200 with
the existing modules and the corresponding LEDs. The send display is not displayed
realistically; in other words, the LEDs do not flash.
Figure 6-6
6.3.3

Working with WBM

Navigation bar
The upper menu bar of WBM provides 3 links:
● Console
● Support
● Log out
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
"LED Simulation" display
This link opens a console window. In this window, you can enter CLI commands. You are
then connected to the switch over a TELNET connection.
This link initiates an Internet connection that takes you directly to the support pages of
SIEMENS AG. This is only possible when the PC supports an Internet connection.
Closes the browser window.
Configuration / diagnostics using remote mechanisms