Restoring The Factory Settings - Siemens SIMATIC NET SCALANCE XC-200 Series Operating Instructions Manual

Industrial ethernet switches
Table of Contents

Advertisement

Maintenance and troubleshooting

6.2 Restoring the factory settings

6.2
Restoring the factory settings
NOTICE
Previous settings
If you reset, all the settings you have made will be overwritten by factory defaults.
NOTICE
Inadvertent reset
An inadvertent reset can cause disturbances and failures in the configured network.
Restoring the factory settings during the startup phase
NOTICE
Reset despite disabled "SELECT/SET" button
Using the "SELECT/SET" button, you can always reset the device parameters to the factory
defaults during the startup phase of the device. This applies also if the "Reset to Factory
Defaults" function was disabled in the configuration. This allows you to reset the device to
the factory defaults in an emergency.
If the function has been disabled in the configuration, it is only disabled on completion of the
startup phase.
To reset the device to the factory defaults during the startup phase, follow the steps below:
1. Turn off the power to the device.
2. Now press the "SELECT/SET" button and reconnect the power to the device while holding
down the button.
3. Hold down the button until the red error LED "F" stops flashing and is permanently lit.
4. Now release the button and wait until the fault LED "F" goes off again.
5. The device starts automatically with the factory defaults.
Restoring the factory defaults during operation
You can also reset the device to the factory defaults during operation, see section "SELECT /
SET button (Page 27)".
58
Operating Instructions, 12/2017, C79000-G8976-C442-03
SCALANCE XC-200

Advertisement

Table of Contents
loading

Table of Contents