Installing Summit Family Switches

Connecting the Ground Cable

WARNING!
Be sure to connect the chassis ground wire before you connect any power cables.
Be sure to disconnect the ground wire after you disconnect all power cables.
To connect the ground wire:
1 Verify that the DC circuit is de-energized.
2 Identify the grounding point on the front panel of the PSU (see
Figure 178: Connecting the Ground Wire
1 = Grounding point
2 = Ground wire

Connecting the PSU to the DC Source Voltage

The DC power connection at your facility must be made by a qualified electrician, following the
instructions in this section.
WARNING!
Always make sure that the DC circuit is de-energized before connecting or disconnecting the DC power
cables on the Summit X650 DC PSU.
CAUTION
Provide proper connection and strain relief on the DC power cables in accordance with all local and
national electrical codes.