Installing the Replacement PSU

To install a replacement Summit X460 DC PSU:
1 Verify that the PSU is right side up (see
2 Carefully slide the PSU all the way into the power supply bay (see
the latch snaps into place.
CAUTION
Do not slam the PSU into the switch.
Figure 217: Installing a Summit X460 DC PSU

Connecting the Ground Wire

To connect the ground wire to the Summit X650 DC PSU:
1 Verify that the DC circuit is de-energized.
2 Identify the grounding point on the front panel of the PSU (see
3 Insert an M3.5 screw (provided) through the ring terminal on the ground wire and into the
grounding point on the PSU.
4 Tighten the screw to 12.6 inch-pounds.
5 Connect the other end of the wire to a known reliable earth ground point at your site.
Figure 218: Connecting the Ground Wire
1
2
1 = Grounding point
2 = Ground wire