Collection levels for log information in trace files:
¢
¢
¢
¢
¢
For details on how to set the collection level, see
Functions on page
Collecting error information using the utility for collecting HDLM
error information (DLMgetras)
HDLM has a utility for collecting HDLM error information (DLMgetras).
By executing this utility, you can simultaneously collect all the information
required for analyzing errors: information such as error logs, integrated trace
files, trace files, definition files, core files, system crash dump files, and
libraries. You can use the collected information when you contact your HDLM
vendor or maintenance company (if there is a maintenance contract for
HDLM).
For details on the DLMgetras utility, see
Error Information on page
Collecting installation error information using the utility for
collecting HDLM installation error information (dlmgetrasinst)
HDLM has a utility for collecting HDLM installation error information
(dlmgetrasinst).
By executing the dlmgetrasinst utility, you can collect system information
and log files needed to analyze errors that occurred during installation. You
can use the collected information when you contact your HDLM vendor or
maintenance company (if there is a maintenance contract for HDLM).
For details on the dlmgetrasinst utility, see
HDLM Error Information on page
2-32
Collects error information at the Error level and higher.
Collects error information at the Warning level and higher.
Collects error information at the Information level and higher.
Collects error information at the Information level and higher
(including maintenance information).
Outputs no trace information
Outputs error information only
Outputs trace information on program operation summaries
Outputs trace information on program operation details
Outputs all trace information