on: Audit log data is collected.
off: Audit log data is not collected.
-audlv audit-log-data-collection-level
-category [[ss] [a] [ca]|all]
-audfac facility-value
Specifies the audit log facility.
Table 6-9 Values of the Audit Log Facility on page 6-29
values of the audit log facility. The default is user.
6-28
Specifies the severity level of audit log data to be collected.
Values Indicating Audit Log Data Collection Levels on page 6-28
describes the values that indicate audit log data collection levels. The
default is 6.
Table 6-7 Values Indicating Audit Log Data Collection Levels
Value (severity)
0
No audit log data is collected.
1
2
Critical-level audit log data is collected.
3
Critical-level and Error-level audit log data is collected.
4
Critical-level, Error-level, and Warning-level audit log data is
collected.
5
6
Critical-level, Error-level, Warning-level, and Informational-
level audit log data is collected.
7
Specifies the categories of audit log data to be collected.
Values Indicating Audit Log Data Categories on page 6-28
values that indicate categories of audit log data. The default is all.
Note that if you enter -category without specifying any category (ss,
a, ca, or all), it is assumed that all is specified.
Table 6-8 Values Indicating Audit Log Data Categories
Value
Audit log events of the StartStop category are collected.
ss
Audit log events of the Authentication category are
a
collected.
Audit log events of the ConfigurationAccess category are
ca
collected.
Audit log events of the StartStop, Authentication, and
all
ConfigurationAccess categories are collected.
Command Reference
Hitachi Dynamic Link Manager User Guide (for AIX(R))
Explanation
Table 6-8
Explanation
describes the
Table 6-7