HP Surestore Disk Array 12h - And FC60 Service Manual page 535

Hp surestore e disk array fc60 service manual (a5277a)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Code
Description
0x6B
Drive SCSI Channel 1 (53C810)
0x01
diagnostics running
0x6B
Drive SC SI Channel 2 (53C810)
0x02
diagnostics running
0x6B
Drive SCSI Channel 3 (53C810)
0x03
diagnostics running
0x6B
Drive SCSI Channel 4 (53C810)
0x04
diagnostics running
0x6B
Drive SCSI Channel 5 (53C810)
0x05
diagnostics running
0x6B
Drive SCSI Channel 1 (53C825)
0x11
diagnostics running
0x6B
Drive SCSI Channel 2 (53C825)
0x12
diagnostics running
0x6B
Drive SCSI Channel 3 (53C825)
0x13
diagnostics running
0x6B
Drive SCSI Channel 4 (53C825)
0x14
diagnostics running
0x6B
Drive SCSI Channel 5 (53C825)
0x15
diagnostics running
0x6B
Drive SCSI Channel 1 (53C875)
0x21
diagnostics running
0x6B
Drive SCSI Channel 2 (53C875)
0x22
diagnostics running
0x6B
Drive SCSI Channel 3 (53C875)
0x23
diagnostics running
0x6B
Drive SCSI Channel 4 (53C875)
0x24
diagnostics running
0x6B
Drive SCSI Channel 5 (53C875)
0x25
diagnostics running
Comments
Cause / Solution
HW Diag. status
Controller module /
reseat or replace
535

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array fc60

Table of Contents