HP Surestore Disk Array 12h - And FC60 Service Manual page 377

Hp surestore e disk array fc60 service manual (a5277a)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Additional
Additional
Sense
Sense Code
Code
Qualifier
3F
8N
3F
98
Interpretation
Drive No Longer Usable.
The controller has set a drive to a state that prohibits use of the
drive. The value of N in the ASCQ indicates the reason why the
drive cannot be used.
0 - The controller set the drive state to "Failed - Write failure"
1 - Not used
2 - The controller set the drive state to "Failed" because it was
unable to make the drive usable after replacement. A format or
reconstruction error occurred.
3 - Not used
4 - Not used
5 - The controller set the drive state to "Failed - No response"
6 - The controller set the drive state to "Failed - Format failure"
7 - The controller set the drive state to "User failed via Mode
Select"
8 - Not used
9 - The controller set the drive state to "Wrong drive removed/
replaced"
A - Not used
B - The controller set the drive state to "Drive capacity < mini-
mum"
C - The controller set the drive state to "Drive has wrong block
size"
D - The controller set the drive state to "Failed - Controller stor-
age failure"
E - Drive failed due to reconstruction failure at Start of Day
(SOD)
Drive Marked Offline Due to Internal Recovery Procedure
An error has occurred during interrupted write processing caus-
ing the LUN to transition to the DEAD state. Drives in the drive
group that did not experience the read error will transition to the
Offline state (0x0B) and log this error.