0x224D
No Response From Disk: Logged
when the configuration manager
posts and UA/AEN of ASC/ASCQ =
0x3F/0x85 indicating the controller set
the drive state to "Failed – No
Response".
0x224E
Replaced Disk Failed: Logged when
the configuration manager posts and
UA/AEN of ASC/ASCQ = 0x3F/0x82
indicating the controller set the drive
state to "Failed" be it was unable to
make the drive usable after
replacement.
0x224F
Global Hot Spare Not Large
Enough: Logged when a defined
Global Hot Spare device is not large
enough to cover all of the drives in the
subsystem.
0x2250
LUN Failure: Logged when the
configuration manager posts and
UA/AEN of ASC/ASCQ = 0x3F/0xE0
indicating Logical Unit Failure.
0x2251
Disk Failed Rebuild at Start of Day
(SOD): Logged when the
configuration manager posts and
UA/AEN of ASC/ASCQ = 0x3F/0x8E
indicating that the drive failed due to a
reconstruction failure at SOD.
0x2252
Device Failed During Interrupted
Write: Logged when the specified
device is failed during interrupted
write processing. SK/ASC/ASCQ =
0x06/0x3F/0x98 will be offloaded for
each failing device.
410
Critical
Notification
(0x1)
(0x4)
Critical
Failure
(0x1)
(0x2)
Informational
Notification
(0x0)
(0x4)
Critical
Failure
(0x1)
(0x2)
Critical
State (0x5)
(0x1)
Critical
Notification
(0x1)
(0x4)
Drive (0x1)
Drive (0x1)
Drive (0x1)
Volume (0xD)
Drive (0x1)
Drive (0x1)