Status
AM60: OPTIMAL
STM: OPTIMAL (OPT)
AM60: NON-EXISTENT
STM: No Disk (NIN)
AM60: UNASSIGNED
STM: OPTIMAL (OPT)
AM60: FAILED--CAUSE
UNKNOWN
STM: FLT - 3
AM60: REPLACED
STM: OFF - 4
AM60: WRONG DRIVE
REMOVED OR REPLACED
STM: FLT - 9
AM60: OFFLINE--
INTERNALLY MARKED OUT
OF SERVICE
STM: OFF - 11
AM60: NON-SUPPORTED
CHANNEL
STM: FLT - 17
Definition/Action
The disk is operating normally.
No action is required.
The disk array controller has no knowledge of a disk in this
slot. This may be caused by no disk being installed, or a disk
that never responds to a SCSI command from the controller.
No action is required.
The disk is a member of the unassigned disk group. It is
available for use in a LUN or as a hot spare.
No action is required.
The disk has failed due to an unknown condition.
Replace the disk.
The disk has been replaced. The disk will maintain this status
until the original data has been rebuilt or copied to the disk.
No action is required.
The wrong disk was removed or replaced from a degraded
LUN. The new disk gets this status.
Reinstall the original disk.
A disk has been installed that was part of another LUN,
possibly in another disk array. The disk array attempts to
recreate the original LUN, but because some of the disk are
missing, the disk is marked OFFLINE. The newly created LUN
will also be assigned a status of DEAD.
Unbind the LUN the disk array has created. This will return the
disk to UNASSIGNED status.
The command issued specified an invalid channel.
Retry the command using the proper channel.