Major Event Log Entries - HP Surestore Disk Array 12h - And FC60 Service Manual

Hp surestore e disk array fc60 service manual (a5277a)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Major Event Log Entries

Event
Number
Event Description
0x1001
Channel Failure: Logged when the
parallel SCSI destination driver detects
a channel failure
0x1007
Memory Allocation Failed: Logged
when memory allocation failed
0x1009
Memory Parity Error: Logged when a
memory parity error is detected by the
destination driver
0x100A
Disk Check Condition: The driver
was unable to recover the specified
device. Returned a check condition to
the driver and driver retries have been
exhausted
0x100B
Destination SOD Error: Logged when
the destination driver can't complete
SOD initialization successfully
0x100E
Unexpected Interrupt: Logged due to
an unexpected interrupt with no active
device on chip
0x100F
Bus Parity Error: Logged when a Bus
Parity error is detected by the
destination driver
Priority
Category
Informational
Failure
(0x0)
(0x2)
Informational
Error (0x1)
(0x0)
Informational
Error (0x1)
(0x0)
Informational
Error (0x1)
(0x0)
Informational
Error (0x1)
(0x0)
Informational
Error (0x1)
(0x0)
Informational
Error (0x1)
(0x0)
Component
Chip (0XC)
Controller
(0x8)
Controller
(0x8)
Drive (0x1)
Controller
(0x8)
Controller
(0x8)
Controller
(0x8)
389