HP Surestore Disk Array 12h - And FC60 Service Manual page 383

Hp surestore e disk array fc60 service manual (a5277a)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Additional
Additional
Sense
Sense Code
Code
Qualifier
85
01
87
00
87
08
87
0C
87
0E
88
0A
8A
00
8A
01
8A
10
Interpretation
Drive IO Request Aborted
IO Issued to Failed or Missing drive due to recently failed
removed drive. This error can occur as a result of I/Os in
progress at the time of a failed or removed drive.
Microcode Download Error
The controller detected an error while downloading microcode
and storing it in non-volatile memory.
Incompatible Board Type For The Code Downloaded
Download failed due to UTM LUN number conflict
Controller Configuration Definition Inconsistent with Alternate
Controller
Subsystem Monitor NVSRAM values configured incorrectly.
Illegal Command for Drive Access
The initiator attempted to pass a command through to a drive
that is not allowed. The command could have been sent in
pass-thru mode or by attempting to download drive microcode.
Illegal Command for the Current RAID Level
The controller received a command that cannot be executed on
the logical unit due to its RAID level configuration. Examples
are parity verify or repair operations on a RAID 0 logical unit.
Illegal Request- Controller Unable to Perform Reconfiguration
as Requested
The user requested a legal reconfiguration but the controller is
unable to execute the request due to resource limitations.
383

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array fc60

Table of Contents