Event
Number
Event Description
0x1101
SCSI Chip Exception Condition:
Logged when the SRC driver detects
an exception condition from the SCSI
chip
0x1102
Host SCSI Bus Reset: Logged when
the source SCSI driver asserts the
RESET signal on the host SCSI bus.
This is usually done as a response to
have a host bus reset propagated to it
by the alternate controller in a cluster
environment.
0x1103
Host SCSI Bus Reset Received:
Logged when a host bus reset was
received and the controller is going to
propagate it to the alternate controller
in a wolf pack environment. Log
entries for Host Bus Reset Received
and Host Bus Reset should always
appear in pairs in the system log.
0x1104
Unknown Interrupt: Logged when
the source SCSI driver detects an
unknown interrupt
Priority
Category
Informational
Error (0x1)
(0x0)
Informational
Notification
(0x0)
(0x4)
Informational
Notification
(0x0)
(0x4)
Informational
Error (0x1)
(0x0)
Component
Controller
(0x8)
Controller
(0x8)
Controller
(0x8)
Controller
(0x8)
391