Failing
Continue
component
after failure
Fibre Channel
No on path to
cable
failed cable;
Yes if array has
dual controller
modules and
alternate paths
have been
configured
140
What happens and how to recover
I/O operations fail along the path through the failed cable. If the host
has two Fibre Channel adapters connected to a dual-controller module
disk array, the array can be accessed through the operational path if
primary and alternate paths have been configured in LVM. If so, LVM
switches automatically and transparently to the alternate path. The
authorized service provider hot-swaps the failed cable