Moving this type
to a slot previously
of disk....
occupied by this type of
disk....
LUN
None or Unassigned
Global Hot Spare
Failed LUN Disk
Optimal LUN Disk (original
disk moved to another slot in
the array)
Global hot spare
None or Unassigned
Global Hot Spare
Failed LUN Disk
Optimal LUN Disk (original
disk moved to another slot in
the array
Unassigned or new
None or Unassigned
Global Hot Spare
Failed LUN Disk
Optimal LUN Disk (original
disk moved to another slot in
the array)
272
results in this behavior.
Disk becomes unassigned. All data on disk is lost.
Disk becomes a global hot spare. All data on disk is
lost.
Disk replaces failed disk and becomes part of new
LUN. All original LUN data on disk is lost.
Disk becomes part of LUN. All original LUN data on
disk is lost.
Disk remains global hot spare
Disk remains global hot spare
Disk replaces failed disk and becomes part of LUN
Disk becomes part of LUN.
Disk remains unassigned.
Disk becomes a global hot spare.
Disk replaces failed disk and becomes part of LUN.
Disk becomes part of LUN.
Need help?
Do you have a question about the Surestore Disk Array 12h - And FC60 and is the answer not in the manual?
Questions and answers