Additional
Additional
Sense
Sense Code
Code
Qualifier
95
02
98
01
98
02
98
03
A0
00
A1
00
A4
00
386
Interpretation
Controller Removal/Replacement Detected or Alternate Con-
troller Released from Reset
The controller detected the activation of the signal/signals used
to indicate that the alternate controller has been removed or
replaced.
The controller has determined that there are multiple sub-enclo-
sures with the same ID value selected.
Sub-enclosure with redundant ESMs specifying different Tray
levels.
Sub-enclosure ESMs have different firmware levels
Write Back Caching Could Not Be Enabled
The controller could not perform write back caching due to a
battery failure or discharge, Two Minute Warning signal from
the UPS, or an ICON failure.
Write Back Caching Could Not Be Enabled - RDAC Cache Size
Mismatch
The controller could not perform write back caching due to the
cache sizes of the two controllers in the RDAC pair not match-
ing.
Global Hot Spare Size Insufficient for All Drives in Subsystem.
A defined Global Hot Spare is not large enough to cover all of
the drives present in the subsystem. Failure of a drive larger
than the Global Hot Spare will not be covered by the Global Hot
Spare drive.