Failing
Continue
component
after failure
Fibre Channel
No on path to
cable
failed cable;
Yes if array has
dual controller
modules and
alternate paths
have been
configured
136
What happens and how to recover
I/O operations fail along the path through the failed cable. If the
host has two Fibre Channel adapters connected to a dual-
controller module disk array, the array can be accessed through
the operational path if primary and alternate paths have been
configured in LVM. If so, LVM switches automatically and
transparently to the alternate path. The authorized service
provider hot-swaps the failed cable.