HP Surestore Disk Array 12h - And FC60 Service Manual page 375

Hp surestore e disk array fc60 service manual (a5277a)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Additional
Additional
Sense
Sense Code
Code
Qualifier
29
04
29
81
29
82
2A
01
2A
02
Interpretation
Device Internal Reset
The controller has reset itself due to an internal error condition.
Default Configuration has been Created
The controller has completed the process of creating a default
logical unit. There is now an accessible logical unit that did not
exist previously. The host should execute its device scan to find
the new logical unit.
Controller Firmware Changed Through Auto Code Synchroni-
zation
The controller firmware has been changed through the Auto
Code Synchronization (ACS) process.
Mode Parameters Changed
The controller received a request from another initiator to
change the mode parameters for the addressed logical unit.
This error notifies the current initiator that the change occurred.
This error may also be reported in the event that Mode Select
parameters changed as a result of a cache synchronization
error during the processing of the most recent Mode Select
request.
Log Parameters Changed
The controller received a request from another initiator to
change the log parameters for the addressed logical unit. This
error notifies the current initiator that the change occurred. This
error is returned when a Log Select command is issued to clear
the AEN log entries.