Status
AM60: READ FAILED
STM: FLT - 19
AM60: WRONG BLOCK SIZE
STM: OFF - 22
AM60: DISK LOCKED OUT
STM: UNSUPP
AM60: NON-SUPPORTED ID
STM: FLT - 33
AM60: NO RESPONSE OR
DEFINED GLOBAL HOT
SPARE--DRIVE IS MISSING
STM: FLT - 35
AM60: CAPACITY LESS
THAN MINIMUM
STM: OFF - 38
AM60: NON-SUPPORTED
CHANNEL & ID
STM: FLT - 49
AM60: FORMAT OR
RECONSTRUCT FAILED
STM: FLT - 51
AM60: WRITE FAILED
STM: FLT - 67
AM60: UNDEFINED
STM: FLT - xxx
AM60: FAILED VIA MODE
SELECT
STM: FLT - 83
364
Definition/Action
The disk array could not read from the disk.
Replace the failed disk.
The disk uses an incompatible block size (not 512 bytes).
Replace with a supported disk.
The disk is not supported.
Install a supported disk.
The command made a request using an unsupported ID.
Retry the command with the proper parameters.
The disk is not responding. It may have failed or been
removed.
Replace or reinstall the disk.
A disk was replaced by a disk with lower capacity.
Install disk with the proper capacity.
The disk is unsupported.
Install a supported disk.
The command made a request to an unsupported channel
and ID.
Retry the command using the proper channel & ID.
The disk failed while being formatted or rebuilt.
Replace the disk.
The disk array could not write to the disk.
Replace the failed disk.
The disk is an unknown state.
The disk was failed using a host-initiated command.