HP Surestore Disk Array 12h - And FC60 Service Manual page 388

Hp surestore e disk array fc60 service manual (a5277a)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Additional
Additional
Sense
Sense Code
Code
Qualifier
E0
20/21
388
Interpretation
Fibre Channel Destination Channel Error
ASCQ = 20: Indicates redundant path is not available to
devices
ASCQ = 21: Indicates destination drive channels are connected
to each other
Sense byte 26 will contain the Tray ID
Sense byte 27 will contain the Channel ID