HP Surestore Disk Array 12h - And FC60 Service Manual page 382

Hp surestore e disk array fc60 service manual (a5277a)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Additional
Additional
Sense
Sense Code
Code
Qualifier
49
80
4B
00
4E
00
5D
80
80
02
80
03
84
00
84
06
382
Interpretation
Drive Reported Reservation Conflict
A drive returned a status of reservation conflict.
Data Phase Error
The controller encountered an error while transferring data to/
from the initiator or to/ from one of the drives.
Overlapped Commands Attempted
The controller received a tagged command while it had an
untagged command pending from the same initiator or it
received an untagged command while it had a tagged com-
mand(s) pending from the same initiator.
Disk SMART Event (Self-Monitoring Analysis and Reporting
Technology)
Bad ASC code detected by Error/ Event Logger
Error occurred during data transfer from SRM host.
Operation Not Allowed With the Logical Unit in its Current State
The requested command or Mode Select operation is not
allowed with the logical unit in the state indicated in byte 76 of
the sense data. Examples would be an attempt to read or write
a "dead" logical unit or an attempt to verify or repair parity on a
"degraded" logical unit.
LUN Awaiting Format
A mode select has been done to create a LUN but the LUN has
not been formatted.