HP Surestore Disk Array 12h - And FC60 Service Manual page 414

Hp surestore e disk array fc60 service manual (a5277a)
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

0x2703
Recovered Processor DRAM Error:
Logged when the controller has
encountered recoverable processor
DRAM ECC errors (below the
maximum threshold)
Event
Number
Event Description
0x2800
Power Supply State Changed:
Logged when a power supply
changes state
0x2801
UPS Battery Supplying Power to
Subsystem: The UPS battery is now
supplying power to the subsystem.
0x2802
UPS Battery Good: The UPS battery
has charged and transitioned to the
good state
0x2803
UPS Battery 2 Minute Warning: The
UPS battery has transitioned given
the 2 minute warning. The UPS has
signaled that it has 2 minutes of
power left before failing. The
controllers will flush any dirty data in
their caches and turn off data
caching.
0x2805
Line State Change: Logged when a
discreet line state change is detected
and an AEN is posted. This can either
be a good to bad transition or bad to
good. This does not include the cache
battery line. Cache battery events are
logged by the cache manager
414
Informational
Notification
(0x0)
(0x4)
Priority
Category
Informational
Notification
(0x0)
(0x4)
Informational
Notification
(0x0)
(0x4)
Informational
Notification
(0x0)
(0x4)
Informational
Notification
(0x0)
(0x4)
Informational
Notification
(0x0)
(0x4)
Controller
(0x8)
Component
Power Supply
(0x2)
Battery (0x9)
Battery (0x9)
Battery (0x9)
Unknown
(0x0)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array fc60

Table of Contents